HOME > Automatic Door > Sensor for Automatic Door > Photoelectric Safety Sensor

Safety For Automatic Doors

Automatic Door - Photoelectric Safety Sensor

Infrared barrier composed by an emitter and a receiver in cylindrical or rectangular heads with integrated amplifierAutomatic Door - Photoelectric Safety Sensor
Automatic Door - Photoelectric Safety SensorThe next generation small-sized infrared beams that can be discreetly fitted into the profiles of single or double doors and which can also be used for specific applications (railways, security entrances, etc.).
The Microcell range is available in several versions:
  • Microcell One: barrier composed by plug-in cylindrical heads with a 5 m cable and a control housing with one relay
  • Microcell Two : barrier composed by plug-in cylindrical heads with a 5 m cable and a control housing with two relays
  • Microcell Three: barrier composed by plug-in cylindrical heads with a 5 m cable and a surveillable control housing with transistor output
  • Microcell Four: barrier composed by rectangular heads connected in series with a 5 m cable. Available in both 'normal' N (NPN-PNP) and 'reverse' R output versions
    Notes:
  • the Microcell range is available either in single (-S) or in double beam version (-D)
  • an optional 10 m cable (-L) is also available for the whole Microcell range
The Microcell range is designed for the safety of pedestrian doors and is featured by a flexibility and an easiness for universal installations
  • reduced size for easy fittings in most of door profiles
  • enables a mounting very close to the floor (20cm - 40cm) as well as an important range (5m - 10m) and can be lightly out of alignment
  • protected against short time wrong connections and immuned to the ambient light (sunlight or artificial lighting)
  • totally immune to interference and complies with the European standards (89/336/EEC)
  • Microcell Two complies with ESC standards, and with the French Ministerial Order on automatic doors in the workplace
  • Microcells Three and Four comply with the German directive ZH 1/494 on windows and doors activated by external energy sources
  • plug supplied with a special sleeve that prevents from moisture problems (Microcells One, Two, Three)

Description
Automatic Door - Photoelectric Safety Sensor
Automatic Door - Photoelectric Safety Sensor
Automatic Door - Photoelectric Safety Sensor
Sensing Fields
Single Beam
Double Beam
Automatic Door - Photoelectric Safety Sensor
Automatic Door - Photoelectric Safety Sensor

Technical Specifications
TechnologyActive infrared,
microprocessor (Microcell One, Two and Three)
analogue (Microcell Four)
Mounting HeightMin. 0.2m above the floor
Distance Between BeamsMin. 0.3m (crossed beams)
Distance In Relation To The Door Plane2cm
Minimum Range1m
Maximum Range5m - for min. mounting height of 0.2m
10m - for max. mounting height of 0.4m
Half-Opening Angle Of The Beam
Detection ModePresence (beam interruption)
Response Timel
  • Transistor Output (Microcell Three and Four)
  • Relay Output (Microcell One and Two)

< 10ms
< 40ms
Hold Time
  • Relay Output (Microcell One and Two)

300ms
Supply Voltage (Microcell One and Two)
                         (Microcell Three and Four)
12-24V AC10%
12-24V DC-5% / +30%
12-24V DC-5% / +20%
Current Consumption< 100mA
Output (Microcell One and Two)
  • Relay Contact Ratings (max. voltage)
  • Relay Contact Ratings (max. current)
  • Maximum Switching Power
1 or 2 relays (free potential contact)
50V DC / 50V AC
1A (resistive)
30W DC / 50VA (AC)
Output (Microcell Three and Four)
  • Relay Contact Ratings (max. voltage)
  • Relay Contact Ratings (max. current)
  • Voltage Drop
Open collector transistor (NPN or PNP)
30V DC
20mA
< 2V at 20mA
Signal1 LED per barrier
(Microcell One, Two and Three: in the control housing)
(Microcell Four: behind the receiver housing)
Adjustment
(by dip switch - Microcell One and Two)
Single / double barrier
Standard / inverted / outputs
Reduced / nominal range
Test position
Adjustment
(by dip switch - Microcell Three and Four)
NPN / PNP outputs
Normal / inverted outputs
Reduced range B / nominal range B
Reduced range A / nominal range A
Temperature Range-20°C to + 55°C
Immunity
  • Sunlight
  • Incandescent Lamp
  • Electromagnetic Compatibility

75000 lux
25000 lux
According to 89/336/EEC
Waterproof HeadsIP 65 (DIN 40050)
Dimensions
Cylindrical Heads (Microcell One, Two and Three)
  • Heads
  • Control Housing
Rectangular Heads (Microcell Four)
  • Heads


Housing: 10mm (built-in) x 12.4mm (diameter)
Collar: diameter 15.6mm
78mm(L) x 50mm(W) x 28mm(H)

124mm(L) x 9mm(W) x 9.5mm(H)
Cable Length5m (10m optional)
Weight
Cylindrical Heads (Microcell One, Two and Three)
  • Emitterl
  • Receiverl
  • Control housing
Rectangular Heads (Microcell Four)
  • Emitterl
  • Receiver


0.140Kg (5m) / 0.270Kg (10m)
0.140Kg (5m) / 0.270Kg (10m)
0.060Kg

0.150Kg (5m) / 0.290Kg (10m)
0.150Kg (5m) / 0.290Kg (10m)
MaterialABS
Housing Colour
(Microcell One, Two and Three)
(Microcell Four)

Transparent
Black
Cable Colour
Cylindrical Heads (Microcell One, Two and Three)
  • Emitterl
  • Receiver
Rectangular Heads (Microcell Four)


Black
Grey
Grey